Signal conditioner
   
FieldSens
page 1
 


Download datasheet





MULTI-CHANNEL MULTI-PURPOSE SIGNAL CONDITIONER FOR FIELD APPLICATIONS

Use with Opsens’ WLPI fiber optic sensors ——  
• Pressure • Temperature • Strain • Position

 


•  Up to 32 measurement channels

•  High linearity and precision

•  RS-232 and RS-485 serial output

•  Tabletop and wall mount versions

•  PLC optional control for data    acquisition and extended control    capabilities

•  LCD screen display

 


The FieldSens is a multi-channel, multi-purpose signal conditioner to be used with any of Opsens’ interferometric fiber optic sensors, i.e. the WLPI fiber optic sensors, for temperature, pressure, strain, and position measurements.

At the heart of the FieldSens is the Opsens’ White Light Polarization Interferometry (WLPI) technology (patent pending) which provides a mean for making accurate and absolute measurements of the path length difference of any type of interferometric fiber optic sensors, whose difference varies according to the measurand of interest.

The FieldSens is offered in a tabletop version or a wall mount version and comes standard with a LCD screen display*, a RS-232 and RS-485 serial interface outputs.  It provides sequential readings over up to 32 measurement channels with a ±0.01% full scale precision.

A PLC controller is also available in option which offers extended control capabilities through a wide range of input/outputs and internal processing, data acquisition capability and different communication hardware and software protocols.

* Display is not available on the 32-channel model

 

 

 
 
 


•  Multi-point long-term monitoring

•  In-situ process monitoring

•  Civil engineering and geotechnical    applications

•  High voltage environments

•  EMI, RFI and microwave environments

•  Nuclear and hazardous environments

 

 

 


Signal conditioner
   
FieldSens
page 2
 

Number of channels

8, 16 or 32

Compatibility

All Opsens WLPI fiber optic sensors

Full scale

30 000 nm (path length difference)

Resolution

±0.003 % of F.S. (no averaging)

Precision

±0.01 % of F.S. @ ±3.3 sigma limit (99.9 % confidence level)

Sampling rate

20 Hz standard (rate given for a fixed channel)

Channel scanning rate

6.67 Hz maximum (channel-to-channel scan period = 150 ms)

Output interface

RS-232 and RS-485 serial output (SCPI protocol)

I/O and control options

Programmable Logic Control (PLC) unit with various I/O

Display

LCD screen display standard (not available on 32-channel model)
Can be ordered without display

Input power

9 to 24 VDC (AD/DC wall-transformer adapter included)

Consumption

2.5 Watt typical

Storage temperature

- 40 °C to 70 °C

Operating temperature

- 40 °C to 60 °C

Humidity

95 % non condensing

Light source life span

40 000 hours MTBF

 